1.
Chinese Journal of Laboratory Medicine ; (12): 1087-1092, 2022.
Article in Chinese | WPRIM | ID: wpr-958625

ABSTRACT

Objective:To establish a matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) method for the direct detection of serum M protein without antibody enrichment, and to assess its detection performance.Methods:Method establishment. A total of 712 waste serum samples were collected from patients who applied for the M protein identification test in Beijing Chaoyang Hospital affiliated to Capital Medical University. The immunoglobulin light chain was obtained by reduction of IgG and IgA by TCEP, and the detection method was preliminarily determined. The waste serum samples from 20 healthy people were collected to determine the range of mass-to-charge ratios of κ and λ light chain ions. 8 parallel tubes and 8 batches were set up for intra-and inter-batch reproducibility evaluation. 10-fold, 100-fold and 200-fold diluted M protein from 23 positive samples were detected by established MALDI-TOF MS method, and its sensitivity was evaluated. 3 methods of IFE, SPE and MALDI-TOF MS were used to detect M protein simultaneously, and the coincidence rate between MALDI-TOF MS and IFE and SPE was calculated.Results:The repeatability within and between batches was 100%, respectively. The original, 10-, 100-and 200-fold dilutions of 23 M protein-positive samples were determined, and the detection limit of MALDI-TOF MS for M protein was 0.06-0.18 g/L. IFE as the gold standard, the overall coincidence rates of SPE and MALDI-TOF MS were 85.9% and 92.3%, respectively, and the positive coincidence rates of SPE and MALDI-TOF MS were 72.8% and 99.7%, respectively, of the 712 samples. Among the different types of M-proteins, MALDI-TOF-MS agreed 100% with IFE M-protein results for IgA, IgD, IgM, free light chain type and biclonal group, while the agreements of SPE for IgM, IgA and free light chain samples were only 66.7%, 58% and 19.5%, respectively. One positive sample in the IgG group was not detected by MALDI-TOF MS. 23 M-proteins positive samples were diluted by original, 10, 100 and 200 times to access the sensitivity of MALDI-TOF MS method. The coincidence rate of MALDI-TOF MS was 100% and IFE was 96% at 10-fold dilution. The coincidence rate of IFE was 28% and 23% of MALDI-TOF MS at 100-fold and 200-fold dilution, respectively.Conclusions:A MALDI-TOF MS method for the detection of serum M-proteins was successfully established. This method has the advantages of high detection throughput, fast speed, good sensitivity, specificity and coincidence rate.

SELECTION OF CITATIONS
SEARCH DETAIL